This paper investigates the effect introduced by the deviation from criticality in the generation of two energy group macroscopic data (diffusion coefficients and cross-sections) typically used by core simulators. Such tools are based on data adjusted to mimic a critical system. This adjustment is usually performed using a B_1 homogeneous method. This method is also used in the present paper to generate neutron energy spectra deviating from criticality, spectra thereafter utilized to condense macroscopic data to two energy groups. For deviations from criticality in the range of ±20β_(eff) for a system representative of Pressurized Water Reactor conditions, it was found that the relative deviation from critical conditions amounts to nearly ±10% in the thermal group flux. In terms of condensed macroscopic data, the largest deviations are observed on the isotropic and anisotropic scattering cross-sections, with the largest deviations reaching ±4000 pcm. For the data used in two-group diffusion-based core simulators, the largest deviations occur for the removal cross-section, amounting to ±3000 pcm. The deviations from the criticality-adjusted macroscopic data are significant, and might have a large impact in reactor transients largely deviating from criticality. Criticality-adjusted material data should thus be used with care in such situations. This study also demonstrates the need in developing a methodology in cross-section preparation and core simulations to account for this effect.
机译:本文研究了核心仿真器通常使用的两个能级宏观数据(扩散系数和横截面)的生成中,由于偏离临界点而产生的影响。此类工具基于经过调整以模仿关键系统的数据。通常使用B_1同质方法执行此调整。该方法在本论文中还用于生成偏离临界点的中子能谱,此后的谱用于将宏观数据浓缩为两个能级。对于代表压水反应堆条件的系统,其临界值偏差在±20β_(eff)范围内,发现在热基团通量中,临界值的相对偏差接近±10%。就压缩的宏观数据而言,在各向同性和各向异性散射截面上观察到最大偏差,最大偏差达到±4000 pcm。对于两组基于扩散的岩心模拟器中使用的数据,去除横截面的最大偏差为±3000 pcm。与临界值调整后的宏观数据的偏差很大,并且可能对很大程度上偏离临界值的反应堆瞬变产生重大影响。因此,在这种情况下应谨慎使用经过关键度调整的材料数据。这项研究还证明了在横截面制备和岩心模拟中开发一种方法以解决这一问题的必要性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号