Injecting 3rd harmonic into the input curent to improve the power factor of DCM buck PFC converter

机译:在输入电流中注入三次谐波以提高DCM降压PFC转换器的功率因数

获取原文

摘要

The conventional Buck PFC converter adopts constant duty cycle control (CDCC), which can improve the PF to some degree. However, the peak and RMS values of the inductor current are large, which also occurs to the switch and diode. This paper derives the expressions of the input current and PF of DCM Buck PFC converter, and based on which, a kind of injecting 3rd current harmonic control (ICHC) is proposed so as to improve the PF in the whole input voltage range. Besides a higher PF, the proposed novel control achieves a lower output voltage ripple, a smaller rms value of the inductor current and a higher efficiency than the conventional control. The experimental results from a 120 W universal input prototype are presented to verify the validity of the proposed method.
机译:常规的Buck PFC转换器采用恒定占空比控制(CDCC),可以在一定程度上提高PF。但是,电感器电流的峰值和RMS值都很大,这在开关和二极管中也会发生。本文推导了DCM Buck PFC变换器的输入电流和PF的表达式,并在此基础上提出了一种注入式三次电流谐波控制(ICHC),以提高整个输入电压范围内的PF。除了较高的PF外,所提出的新颖控制还实现了比传统控制更低的输出电压纹波,更小的电感电流均方根值和更高的效率。提出了来自120 W通用输入原型的实验结果,以验证所提出方法的有效性。