In this paper, two methods of shielding effectiveness (SE) measurements in a partially anechoic chamber are presented. The first measurement method is based on measuring S21 parameters using the network analyzer. In the second method, the spectrum analyzer is used for electric field measurements in two set-ups. In the first set-up, the tracking generator is supported by the Software Spike (Signal Hound) to automated measurement, while in the second set-up the signal generator is used for point-to-point electric fields measurements. These measurement methods are conducted on two enclosure models with a slot aperture. The numerical SE simulations are conducted based on the compact Transmission-Line Matrix (TLM) method by using the commercial software (CST). The numerical analysis of shielding properties of a protective enclosure has been performed by the monopole-receiving antenna placed inside. Finally, the simulated results are compared with the experimental ones. The goal of this paper is to shown that the SE measurement in improvised partially anechoic chamber can be made with very accurate results.
机译:在本文中,提出了局部放置腔室中的两种屏蔽有效性(SE)测量的方法。第一测量方法基于使用网络分析仪测量S21参数。在第二种方法中,频谱分析仪用于两个设置中的电场测量。在第一次设置中,跟踪发生器由软件尖峰(信号捕猎)支持到自动测量,而在第二个设置中,信号发生器用于点对点电场测量。这些测量方法在具有槽孔的两个外壳模型上进行。使用商业软件(CST)基于紧凑的传输线矩阵(TLM)方法进行数值SE模拟。通过放置在内部的单极接收天线执行了保护外壳的屏蔽性能的数值分析。最后,将模拟结果与实验结果进行比较。本文的目的是表明,可以用非常精确的结果制造即可改进的部分放置室中的SE测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号