首页> 外文会议>Air quality measurement methods and technology conference >Using Automated Eddy-covariance Stations for Studying Landfill Methane Emissions
【24h】

Using Automated Eddy-covariance Stations for Studying Landfill Methane Emissions

机译:使用自动涡流协方差站研究垃圾填埋场甲烷排放

获取原文

摘要

Our results show that the eddy covariance can be used to quantify the landfill methane emission as long as certain requirements, relatively flat surface and large enough fetch, are met. Our results show that the methane emission rates at the landfill strongly depend on changes in barometric pressure; i.e., rising barometric pressure suppresses the emission, while falling barometric pressure enhances the emission. There was up to 6-fold variation of methane emissions from day-to-day due to changes in barometric pressure.
机译:我们的结果表明,只要满足某些要求,相对平坦的表面和足够大的提取量,涡旋协方差可用于量化垃圾填埋场的甲烷排放量。我们的结果表明,垃圾填埋场的甲烷排放率很大程度上取决于大气压力的变化。即,升高大气压可抑制排放,而降低大气压可增强排放。由于大气压力的变化,甲烷排放量每天变化多达6倍。