摘要

The pulse-width modulation (PWM) inverter variable voltage variable frequency speed control systems are widely applied to the modern subway vehicles. The bearing electrical corrosion problems due to the variable frequency power supply have caused serious dangers to the subway operation. In this paper, the bearing current problem of Beijing Metro Line 10 traction motors was analyzed. The common mode equivalent circuit of the motor bearing current was established, and the influence of the ground resistance on bearing current was analyzed. The simulation results showed that the poor earthen condition of motor frame is the reason for the bearing electric erosion. Finally, the new bearing current suppression method was proposed. The appropriate stator ground resistance of the traction motor was determined by the shaft ground resistance and the motor stray capacitances, which could eliminate the bearing current.
机译:脉冲宽度调制(PWM)逆变器可变电压可变频率控制系统广泛应用于现代地铁车辆。 由于变频电源引起的轴承电腐蚀问题对地铁运行引起了严重的危险。 本文分析了北京地铁10线10牵引电机的轴承电流问题。 建立了电机轴承电流的共同模式等效电路,分析了接地电阻对轴承电流的影响。 仿真结果表明,电机框架的差土条件是轴承电腐蚀的原因。 最后,提出了新的轴承电流抑制方法。 通过轴接地电阻和电动机杂散电容确定牵引电动机的适当定子接地电阻,这可以消除轴承电流。