With the purpose of improving the efficiency of anaerobic digestion for waste activated sludge, μs-Pulsed electric field (μs-PEF) has been employed for pretreatment on waste activated sludge and its features of low energy consumption and high efficiency make it a promising method for industry application. In this work, DC corona has been used to assist the μs-PEF treatment on the sludge and the treatment efficiency has been estimated by measuring the soluble chemical oxygen demand, NH3-N and total phosphorus. The influence of the polarity and magnitude of DC voltage on the treatment efficiency has been discussed. Obtained results showed that DC corona assisted PEF has higher treatment efficiency than PEF treatment. It is suggested that electroporation of microbial cell membrane within the sludge is likely to occur easily with the initial treatment of DC corona, which in turn facilitates the disruption of cell membrane.
机译:为了提高废活性污泥的厌氧消化效率,已将μs-脉冲电场(μs-PEF)用于废活性污泥的预处理,其低能耗和高效率的特性使其成为一种有前途的方法。行业应用。在这项工作中,直流电晕已用于辅助污泥的μs-PEF处理,并且通过测量可溶性化学需氧量,NH3-N和总磷来估算处理效率。讨论了直流电压的极性和大小对处理效率的影响。所得结果表明,直流电晕辅助的PEF比PEF的治疗效率更高。有人提出,通过直流电晕的初步处理,污泥中微生物细胞膜的电穿孔很容易发生,这反过来又促进了细胞膜的破坏。