This study proposes an improved template-matching method which can automatically update the normal template heartbeats with the change in heart rate, and compare the input heartbeats with the template to detect abnormal heartbeats in real time. If an input heartbeat has a cross-correlation coefficient of less than 0.6 or a mean-square difference larger than 1.0 in comparison with the template, it is identified as abnormal. The study results show that if the normal template is not updated with the heart rate, normal heartbeats may be misjudged as abnormal when exercise changes the heart rate and heartbeat waveforms. The results also demonstrate that the proposed method can accurately identify abnormal heartbeats of ventricular fibrillation (VF) and ventricular tachycardia (VT) using ECG records 426 and 607 from the Malignant Ventricular Arrhythmia Database.
机译:本研究提出了一种改进的模板匹配方法,可以通过心率的变化自动更新正常模板心跳,并将模板与模板的输入心跳进行比较,以实时检测异常心跳。如果输入心跳具有小于0.6的互相关系数或与模板相比大于1.0的平均平方差,则其被识别为异常。研究结果表明,如果正常模板未以心率更新,则在运动变化心率和心跳波形时,正常心跳可能被误判为异常。结果还证明,该方法可以使用来自恶性心室心律失常数据库的ECG记录426和607准确地识别心室颤动(VF)和心室性心动过速(VT)的异常心跳。