首页> 外文会议>IEEE Power and Energy Society General Meeting >A new efficient algorithm to detect Current Transformer saturation
【24h】

A new efficient algorithm to detect Current Transformer saturation

机译:一种检测电流互感器饱和的高效算法

获取原文

摘要

This paper presents an algorithm to precisely detect the saturation of Current Transformers (CTs). The algorithm is based on first difference of magnitudes of Lissajous Curve. These Lissajous curves are generated using secondary current signal and its first derivative. PSCAD was used to generate secondary current signals for various practical cases of fault currents and MATLAB was used to implement the proposed algorithm. The algorithm is tested for various cases of severe and mild CT saturation. Moreover, the effects of various factors, such as remnant magnetic flux density, noise and burden power factor are studied. Test results reflect that the proposed algorithm efficiently detect the start and end instants of CT Saturation for almost all cases.
机译:本文提出了一种可精确检测电流互感器(CT)饱和度的算法。该算法基于李沙育曲线的幅度的第一差。这些利萨如曲线是使用次级电流信号及其一阶导数生成的。 PSCAD用于生成各种故障电流实际情况的次级电流信号,MATLAB用于实现该算法。针对严重和轻度CT饱和的各种情况测试了该算法。此外,还研究了剩余磁通密度,噪声和负载功率因数等各种因素的影响。测试结果表明,所提出的算法可在几乎所有情况下有效检测CT饱和的开始和结束时刻。