Power transformers play a very critical role in electrical energy transmission. Abnormal performance of transformers would seriously affect the reliability and stability of power system. Non-electrical gas relays are usually used as a main protection of power transformers. Indeed, due to the inherent defects, the gas relay misjudgments happen every year across the world. Given this background, this paper employs a theoretical model and its simulation method to study the relationship between electrical faults and non-electrical pressure variations inside the tank. Based on the essence difference of the pressure characteristics among the internal faults, external faults and normal running condition, a novel transformer protection principle is proposed. Numerical test has indicated that the proposed protection is able to reliably clear the transformer internal faults, even the single-turn fault or other weak faults.
机译:电力变压器在电能传输中起着至关重要的作用。变压器性能异常会严重影响电力系统的可靠性和稳定性。非电气气体继电器通常用作电力变压器的主要保护装置。的确,由于固有的缺陷,全世界每年都会发生对气体继电器的误判。在这种背景下,本文采用理论模型及其仿真方法来研究罐内电气故障与非电气压力变化之间的关系。针对内部故障,外部故障和正常运行状态之间压力特性的本质差异,提出了一种新颖的变压器保护原理。数值测试表明,所提出的保护措施能够可靠地清除变压器内部故障,甚至是单匝故障或其他弱故障。