首页> 外文会议>International foundations congress and equipment expo >Electronic Thickness Gauge Measurements on a 36-year old Steel Bar Mat Reinforced MSE Wall
【24h】

Electronic Thickness Gauge Measurements on a 36-year old Steel Bar Mat Reinforced MSE Wall

机译:电子测厚仪在36岁的钢筋垫增强的MSE墙上的测量

获取原文

摘要

During road realignment activities in 2012 on the Ⅰ-495 Washington Capital Beltway, the Virginia Department of Transportation (VDOT) demolished a MSE wall originally built in 1976. The wall supported traffic on the interstate bridge ramp and was therefore salted each winter as part of VDOT's standard winter maintenance program; the wall did not have any observable performance issues. Demolition provided an opportunity for researchers at the Federal Highway Administration (FHWA) to investigate the condition of the reinforcement in the 36-year old wall and determine any key factors affecting corrosion related to the design, construction, and maintenance practices. Steel and soil samples were collected from various locations behind the concrete panels along the length of the wall to assess the thickness of the remaining zinc coating on the bar mats. This thickness was analyzed as a function of wall elevation and distance from the bridge abutment face. This paper will describe the corrosion sampling and testing program and present preliminary conclusions on the results.
机译:在2012年华盛顿州首都Ⅰ-495号公路的道路改组活动中,弗吉尼亚州交通运输部(VDOT)拆除了最初建于1976年的MSE隔离墙。该隔离墙为州际桥梁坡道上的交通提供了支撑,因此,作为冬季的一部分,每年冬季都要加盐VDOT的标准冬季维护计划;隔离墙没有任何可观察到的性能问题。拆除为联邦公路管理局(FHWA)的研究人员提供了一个机会,以调查36年之久的旧墙中钢筋的状况,并确定影响与设计,施工和维护实践相关的腐蚀的任何关键因素。沿着墙的长度从混凝土面板后面的各个位置收集钢和土壤样品,以评估钢筋垫上剩余的锌涂层的厚度。根据壁高和距桥台面的距离来分析该厚度。本文将描述腐蚀采样和测试程序,并给出有关结果的初步结论。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号