首页> 外文会议>Geothermal Resources Council annual meeting >Evaluation of Inflow Radial Turbo Expander Field Performance for a 25 MW Geothermal Organic Rankine Cycle Train
【24h】

Evaluation of Inflow Radial Turbo Expander Field Performance for a 25 MW Geothermal Organic Rankine Cycle Train

机译:25 MW地热有机朗肯循环列车入流径向涡轮膨胀机现场性能评估

获取原文

摘要

The first phase of a geothermal Organic Rankine Cycle (ORC) power plant was commissioned in October, 2013. The electrical power production capacity of this plant will be in excess of 100 MW when phases two and three are completed in 2015. This geothermal ORC power plant was optimized with normal butane as the working fluid using an inflow radial turbine. The first phase, with nominal power of 45 MW consisted of two power trains. Each power train has a nominal capacity of 22.5 MW electrical power output. In this paper we present the geothermal resource design conditions, the thermodynamic issues for the choice of working fluid, field performance of the inflow radial turbine and comparison with the expected performance.
机译:地热有机朗肯循环(ORC)电厂的第一阶段已于2013年10月投入使用。当第二阶段和第三阶段于2015年完成时,该电厂的电力生产能力将超过100 MW。使用流入的径向涡轮机,以正丁烷作为工作流体对工厂进行了优化。第一阶段的标称功率为45兆瓦,由两个动力总成组成。每个动力传动系的额定输出功率为22.5 MW。在本文中,我们介绍了地热资源的设计条件,工作流体选择的热力学问题,流入型径向涡轮的现场性能以及与预期性能的比较。