Magnetic resonance elastography (MRE) is a phase-contrast MRI based technique that allows quantitative, noninvasive assessment of the mechanical properties of tissues by the introduction of shear waves into the body and measurement of the resulting displacements. In MRE, the calculated stiffness values are affected by noise, which is amplified by the inversion process. It would be useful to know that beyond some SNR threshold, the stiffness values are accurate within some confidence limit. The most common methods to calculate SNR values in MRE are variations of displacement SNR, which estimate the noise in the measured displacement. However, the accuracy of stiffness determination depends not only on the displacement SNR, but also on the wavelength of the shear wave, in turn dependent on the stiffness of the underlying material. More recently, the SNR of the octahedral shear strain (OSS) has been proposed as a more appropriate measure, since shear deformation is the signal in MRE. We also propose here another measure based on the SNR of the Laplacian of the data, since this is the most noise sensitive quantity calculated when performing direct inversion of the Helmholtz equation. The three SNR measures were compared on simulated data for materials of different stiffness with varying amounts of noise using three inversion algorithms commonly used in MRE (phase gradient, local frequency estimation, and direct inversion). We demonstrate that the proper SNR measure for MRE depends on the inversion algorithm used, and, more precisely, on the order of derivatives used in the inversion process.
机译:磁共振弹性显影(MRE)是一种基于相对造影MRI的技术,其允许通过将剪切波引入体内并对所得位移的测量来定量,非侵入性评估组织的机械性能。在MRE中,计算的刚度值受到噪声的影响,该噪声由反转过程放大。知道超出了一些SNR阈值,刚度值在某些信心限制内是准确的。计算MRE中SNR值的最常用方法是位移SNR的变化,这估计了测量位移中的噪声。然而,刚度测定的精度不仅取决于位移SNR,而且取决于剪切波的波长,反过来依赖于下面材料的刚度。最近,已经提出了八面体剪切菌株(OSS)的SNR作为更适当的措施,因为剪切变形是MRE中的信号。我们还在这里提出了基于拉普拉斯的SNR的另一种措施,因为这是在执行亥姆霍兹方程的直接反演时计算的最噪声敏感量。比较三种SNR措施,用于模拟不同刚度材料的模拟数据,其使用MRE(相位梯度,局部频率估计和直接反转)的三个反演算法不同的噪声不同的噪声。我们证明了MRE的适当SNR测量取决于所使用的反转算法,更准确地,在反转过程中使用的衍生物顺序。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号