This paper present new voltage instability detection index (QLVIDI) based on reactive power loss using Synchrophasor technology. The proposed index is fast as compare to the already existing Voltage Instability Monitoring Index (VIMI) and Improved Voltage Instability Monitoring Index (IVIMI). The proposed scheme utilizes reactive power losses in the lines in consideration with direction of active power flow to calculate the time series data of reactive power losses in the buses. This time series data of reactive power loss is useful for the calculation of change in consecutive reactive power loss and change in reactive power loss from base case reactive power loss for developing QLVIDI. The effectiveness of the proposed index is tested in standard IEEE 30 bus system.
机译:本文提出了一种基于同步相量技术的基于无功损耗的新型电压不稳定性检测指标(QLVIDI)。与已经存在的电压不稳定性监测指标(VIMI)和改进的电压不稳定性监测指标(IVIMI)相比,建议的指标很快。所提出的方案利用线路中的无功功率损耗并考虑有功功率流的方向来计算总线中无功功率损耗的时间序列数据。该无功功率损耗的时间序列数据对于计算连续无功功率损耗的变化以及从开发QLVIDI的基本情况下的无功功率损耗的无功功率损耗的变化非常有用。建议的索引的有效性已在标准IEEE 30总线系统中进行了测试。