Switches in shunt hybrid active power filter are prone to damage. However, too much time is needed in traditional fault diagnosis methods with relatively high misdiagnosis rate. A new fault diagnosis method based on voltage distortion is proposed. Open-circuit fault is detected rapidly by catching the distortion of the capacitor voltage and comparing it with the normal value. At the same time, the faulty switch can be located. By this method, the fault location can be diagnosed accurately and rapidly in a half period. Simulation results for open-circuit fault occurred in different locations verified the effectiveness, validity and rapidity of the proposed method.
机译:分流式混合有源电力滤波器的开关容易损坏。然而,在传统的故障诊断方法中需要太多时间,误诊率较高。提出了一种基于电压失真的新故障诊断方法。通过捕捉电容电压的失真并将其与正常值进行比较来快速检测开路故障。同时,可以定位故障开关。通过这种方法,故障位置可以在半期内精确且快速地诊断。不同位置发生开路故障的仿真结果验证了所提出的方法的有效性,有效性和快速性。