A composite insulator using silicone rubber is widely applied to an outdoor insulator instead of a conventional porcelain insulator due to lightweight, easy handling and high pollution resistance of silicone rubber insulator. To understand DC surface insulating performances, the DC flashover inception voltages (FOIV) on silicone rubber sheet sample and porcelain insulator plate sample were measured under positive impulse voltage with or without DC prestressing. As the result, DC prestressing effect of silicone rubber sheet sample and porcelain insulator plate sample is same tendency as general DC prestressing effect under positive impulse voltage application with negative DC prestressing. But, under positive impulse voltage application with positive DC prestressing, FOIV of porcelain insulator plate sample showed a peak at DC prestressing of +20 kV. Moreover, surface resistivity of silicone rubber sheet sample is higher than that of porcelain insulator plate sample. In general, the impulse breakdown strength of insulating material increases under DC prestressing of same polarity. On the other hand, the impulse breakdown strength of insulating material decrease under DC prestressing of reverse polarity. From these result, due to the low surface resistivity of porcelain insulator plate sample, it is considered that FOIV decrease in spite of homo condition because the positive surface charge moves to the vicinity of the counter electrode and act as hetero charge.
机译:使用硅橡胶的复合绝缘子由于硅橡胶绝缘子的轻便,易处理和高耐污染性而被广泛应用于室外绝缘子,而不是传统的瓷绝缘子。为了了解直流表面绝缘性能,在有或没有直流预应力的情况下,在正脉冲电压下测量了硅橡胶板样品和瓷绝缘板样品上的直流闪络起始电压(FOIV)。结果,硅橡胶片样品和瓷绝缘板样品的直流预应力效果与在施加负脉冲预电压和负直流预应力的情况下的一般直流预应力趋势相同。但是,在施加正脉冲直流电压和正直流预应力的情况下,瓷绝缘子板样品的FOIV在直流预应力为+20 kV时出现一个峰值。此外,硅橡胶片样品的表面电阻率高于瓷绝缘板样品的表面电阻率。通常,在相同极性的直流预应力下,绝缘材料的脉冲击穿强度会增加。另一方面,在反极性的直流预应力下,绝缘材料的脉冲击穿强度降低。从这些结果可知,由于瓷绝缘板样品的表面电阻率低,尽管存在均质状态,但由于正表面电荷移动到对电极附近并作为杂电荷而使FOIV降低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号