首页> 外文会议>IEEE Transportation Electrification Conference >Analysis of ground fault currents in isolated and non-isolated charging modules in electric vehicles
【24h】

Analysis of ground fault currents in isolated and non-isolated charging modules in electric vehicles

机译:电动汽车隔离和非隔离充电模块中的接地故障电流分析

获取原文

摘要

The paper compares generic on board charger module (OBCM) topologies with respect to ground fault current detection and interruption. Ground fault current in isolated charging modules is very small due to the galvanic isolation between the input and output sides. In non-isolated charging modules, the paper shows the contributing components of the system to the generation of ground fault current. The ground fault current interrupt circuit is explained and compared in both topologies. Performance and parametric measures are used to compare the two topologies in MATLAB/Simulink.
机译:本文比较了接地故障电流检测和中断方面的通用车载充电器模块(OBCM)拓扑。隔离充电模块中的接地故障电流非常小,这是由于输入侧和输出侧之间的电流隔离所致。在非隔离式充电模块中,本文显示了系统对接地故障电流产生的贡献。两种拓扑都对接地故障电流中断电路进行了解释和比较。性能和参数测度用于比较MATLAB / Simulink中的两种拓扑。