This paper presents a new ventilation wall system (i.e., dynamic storage system) that can be installed in new and refurbished buildings, which is based on the dynamic insulation system using ineluctable ventilation amount and stabilization of the local surface temperature by phase change material. Thermal insulation performance (U_(dyn) value) depending on airflow was measured by a chamber test. In this study, index U_(dyn) is defined by the mean heat flux from the wall to outdoors divided by the environment temperature difference between the indoors and outdoors. The measurement results show that U_(dyn) is 0.1-0.2 W/m~2K (ventilation amount: 0.4 m~3/h).
展开▼
机译:本文介绍了一种新的通风墙系统(即动态存储系统),该系统可以安装在新的和翻新的建筑物中,该系统基于动态绝缘系统,该系统使用不可避免的通风量并通过相变材料来稳定局部表面温度。通过室内试验来测量取决于气流的绝热性能(U_(dyn)值)。在这项研究中,指标U_(dyn)由从墙壁到室外的平均热通量除以室内与室外之间的环境温度差定义。测量结果表明,U_(dyn)为0.1-0.2 W / m〜2K(换气量:0.4 m〜3 / h)。