In this paper we propose a simple reference test object which is to be used as a set up verification device to be tested before High Intensity Radiated Field (HIRF) measurement campaigns on aircraft. This reference object has been designed to take into account both EM and mechanical requirements. It therefore ensures a good level of sensitivity and reproducibility of a reference measured transfer function between the incident E-field and an internal induced current. This object has been calibrated in laboratory using a strip-line which enables to fully control the incident EM field. Finally tests in open test site conditions have been carried out in order to provide reference transfer functions.
机译:在本文中,我们提出了一个简单的参考测试对象,该对象将用作在飞机上进行高强度辐射场(HIRF)测量之前进行测试的设置验证设备。设计该参考对象时要考虑到EM和机械要求。因此,它确保了入射电场和内部感应电流之间的参考测量传递函数的灵敏度和可重复性的良好水平。该对象已在实验室中使用带状线进行了校准,该带状线能够完全控制入射的电磁场。最终,在开放的测试场所条件下进行了测试,以提供参考传递功能。