First Experience in Vacuum Insulated Hot Water Storage with 100 m~3

机译:100 m〜3真空保温热水储藏的初步经验

获取原文

摘要

This article presents the results of an experiment that aimed to determine the effective thermal conductivity of the first 100 m~3 vacuum-insulated hot water heat storage. For this, the store was filled with 82°C hot water. Thereafter, the temperature decrease was measured over 31 days. A U-value of 0.36 W/(m~2·K) was calculated using the energy balance model of Raab. This article also presents some pictures of the construction of the heat store.
机译:本文介绍了旨在确定第一个100 m〜3真空绝热热水储热器的有效热导率的实验结果。为此,商店充满了82°C的热水。此后,在31天内测量温度下降。使用Raab的能量平衡模型计算得出的U值为0.36 W /(m〜2·K)。本文还提供了一些有关储热器构造的图片。