INVESTIGATIONS ON PULSATION-REDUCTION CHARACTERISTICS OF HYDRAULIC ATTENUATOR BASED ON EXPERIMENTAL METHOD

机译:基于实验方法的液压衰减器脉动降低特性研究

获取原文

摘要

Three types of hydraulic attenuators are designed and investigated to study the pulsation-reduction characteristics in hydraulic system. Attenuator test rig is established to obtain pressure signals in time domain and frequency domain (5 Hz to 1200 Hz), respectively. Influences of changing source impedance and loading impedance to the attenuation rate (Ka) and pressure ratio of inlet and outlet (P_(io)) are discussed. Experiment results show that expansion chamber attenuator (ECA) is a better choice for a wide frequency range of pulsation reduction. Two types of perforated tube attenuators (PTA) have better performances in some certain frequency range. The performance of PTA can have further improvements by designing the damping holes diameters. The performance of the attenuator is mainly influenced by pump character and rotating speed. The system loading has limited influence on the performance comparing to source impedance.
机译:设计并研究了三种类型的液压衰减器,以研究液压系统中的脉动衰减特性。建立衰减器测试台,以分别获取时域和频域(5 Hz至1200 Hz)中的压力信号。讨论了源阻抗和负载阻抗的变化对衰减率(Ka)和入口和出口压力比(P_(io))的影响。实验结果表明,扩展室衰减器(ECA)是较宽的脉动降低频率范围的较好选择。两种类型的穿孔管衰减器(PTA)在某些特定频率范围内具有更好的性能。通过设计阻尼孔直径,可以进一步提高PTA的性能。衰减器的性能主要受泵的特性和转速影响。与源阻抗相比,系统负载对性能的影响有限。