摘要

In order to study the voltage distribution in transformer windings under Very Fast Transient Overvoltage (VFTO), a model for transformer windings has been developed based on Multi-conductor Transmission-Lines (MTLs) theory and the computing equations of the model based on Finite-Difference Time-Domain method (FDTD) is deduced. The Vector Fitting method is adopted to treat the frequency-dependent parameter by expanding the time-domain form of internal impedance of the transformer windings into a sum of finite exponential functions which are easy for the time-domain convolution. For validation, an actual transformer winding model has been studied. The calculated result are compared with the measured result and a satisfactory result is obtained.
机译:为了在非常快速的瞬态过电压(VFTO)下的变压器绕组中的电压分布,基于多导体传输线(MTLS)理论和基于有限模型的模型的计算方程式开发了一种用于变压器绕组的模型推导出差分时域方法(FDTD)。采用载体拟合方法通过将变压器绕组的内部阻抗的内部阻抗的时域形式扩展到易于用于时域卷积的有限指数函数的总和来处理频率依赖性参数。为了验证,研究了实际的变压器绕组模型。将计算结果与测量结果进行比较,获得令人满意的结果。