DC bus current harmonics of a three-phase PWM inverter with the zero sequence injection

机译:零序注入的三相PWM逆变器的直流母线电流谐波

获取原文

摘要

Power electronic converters connected to a dc bus are sources of undesirable harmonics towards the dc side due to an inherent high-frequency switching used for the power processing. Three-phase inverters are widely used in many applications like motor drives and active rectifiers. With a SPWM control the dc bus voltage is not fully utilized, so a zero sequence injection method is commonly used to increase the maximum fundamental voltage output. The inverter dc side current harmonics are investigated for a three-phase SPWM inverter with and without zero sequence injection. The results show that the injection of the third harmonic and Min/Max zero sequence will not increase the dc side harmonics. The RMS value of the inverter dc side current is increased less than 1% when the zero sequence is injected.
机译:由于用于功率处理的固有高频开关,连接到dc总线的功率电子转换器是朝向dc侧的有害谐波源。三相逆变器广泛用于许多应用中,例如电动机驱动器和有源整流器。通过SPWM控制,无法充分利用直流母线电压,因此通常使用零序注入方法来增加最大基本电压输出。研究了带有和不带有零序注入的三相SPWM逆变器的逆变器直流侧电流谐波。结果表明,三次谐波和最小/最大零序的注入不会增加直流侧谐波。注入零序时,逆变器直流侧电流的RMS值增加不到1%。