首页> 外文会议>IEEE International Energy Conference >An improved power flow method based on extended chain-table storage structure for distribution network with PV nodes
【24h】

An improved power flow method based on extended chain-table storage structure for distribution network with PV nodes

机译:基于扩展链表存储结构的光伏节点配电网潮流改进方法

获取原文

摘要

Based on an extended chain-table storage structure, an improved power flow method is presented, which can be applied to a distribution network with multi PV nodes. The extended chain-table storage structure is designed on the basis of address-pointer technology describing the radial topology with a reduced memory size. The voltage error of each PV node is adjusted by a reactive power adjusting strategy. The adjusting strategy is based on a multi-variable linear function with an accelerating factor. Finally, this new improved power flow method is realized by the software system developed in VC and the corresponding case study has been done. The experimental data and the further analysis have proved that this method can calculate the power flow of a distribution network with multi PV nodes precisely and fast.
机译:基于扩展的链表存储结构,提出了一种改进的潮流方法,可以应用于具有多个光伏节点的配电网。扩展链表存储结构是基于地址指针技术设计的,该技术描述了具有减小的内存大小的径向拓扑。每个PV节点的电压误差都通过无功功率调整策略进行调整。调整策略基于具有加速因子的多变量线性函数。最后,通过VC开发的软件系统实现了这种改进的潮流算法,并进行了相应的案例研究。实验数据和进一步的分析证明,该方法可以准确,快速地计算出具有多个光伏节点的配电网的潮流。