This paper presents the results of a survey on the reliability of the protective systems of five 240 MW hydro generating units, using operating records that cover 17 years. It includes the computation of reliability indices and the modeling of failures and repairs for the protective systems associated to generators, substations, auxiliary services, turbines and spherical valves. Results show that: i. The most reliable protective systems are those associated to the substations; the second more reliable are the ones associated to the generators. ii. The less reliable protective systems are those associated to the auxiliary services; the second less reliable are those associated to the turbines. iii. Dependency of the protective systems associated to the generators and substations is lower than its security, while the contrary happens for the protective systems of the auxiliary services, turbines and spherical valves. iv. The processes of arrival of false openings, false closings, failures to close and their corresponding repairs are stationary, what means, there is no a pattern of increase or decrease in the occurrence of failures and the duration of repairs.
机译:本文介绍了使用涵盖17年的运行记录的5台240 MW水轮发电机组保护系统可靠性的调查结果。它包括可靠性指标的计算以及与发电机,变电站,辅助服务,涡轮机和球阀相关的保护系统的故障和维修建模。结果表明:i。最可靠的保护系统是与变电站相关的保护系统。第二个更可靠的是与发电机相关的发电机。 ii。可靠性较差的防护系统是与辅助服务相关的防护系统;第二个较不可靠的是与涡轮机相关的那些。 iii。与发电机和变电站相关的保护系统的依赖性低于其安全性,而辅助服务,涡轮机和球形阀的保护系统则相反。 iv。错误开口,错误闭合,关闭失败及其相应维修的到达过程是固定的,这意味着,故障发生和维修时间没有增加或减少的模式。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号