The transient voltage unbalance is the major problem that limits the application of series-connected IGBTs in high voltage and high power converters. The asynchronous gate delay which causes that series-connected IGBTs do not turn-on and turn-off at the same time results in the most serious unbalanced voltage sharing. The active voltage control technique is proposed in this paper to solve the asynchronous gate delay problem. By sampling the feedback signal caused by unbalanced voltage, the microcontroller generates a time delay for gate driver to compensate the asynchronous gate delay. The most vital part of active voltage control is the status feedback circuit which is also given in detail in this paper. The function of the status feedback circuit and the effect of active voltage control are verified in a two series-connected HV-IGBTs platform in rated operation (5kV bus voltage and 600A load current).
机译:瞬态电压不平衡是限制在高压和高功率转换器中串联连接的IGBT的主要问题。异步栅极延迟导致串联连接的IGBT不会导通和关闭同时导致最严重的不平衡电压共享。本文提出了有源电压控制技术,以解决异步栅极延迟问题。通过采样由不平衡电压引起的反馈信号,微控制器为栅极驱动器产生时间延迟,以补偿异步栅极延迟。主电压控制的最重要部分是本文还详细给出的状态反馈电路。状态反馈电路的功能和主动电压控制的效果在额定操作的两个串联的HV-IGBT平台中验证(5kV母线电压和600A负载电流)。