Fault diagnosis of wind turbine using control loop current signals

机译:使用控制回路电流信号的风力涡轮机的故障诊断

获取原文

摘要

This paper presents a fault diagnosis method for direct-drive wind turbine with permanent magnet synchronous generator (D-PMSG) by using generator control loop current signals. In this method, the Vold-Kalman filtering order tracking technique is used to track the fault characteristic harmonic components from q-axis current signals. Then the envelopes of amplitudes of the fault harmonic components are calculated and applied for fault diagnosis of D-PMSG. To verify the proposed method, the simulation model is established in MATLAB/Simulink and the simulations are carried out. The results show that the proposed method is effective, where blade imbalance and winding asymmetry faults are successfully detected.
机译:本文通过使用发电机控制回路电流信号,提出了一种具有永磁同步发电机(D-PMSG)的直驱风力涡轮机的故障诊断方法。在该方法中,Vold-Kalman滤波顺序跟踪技术用于跟踪来自Q轴电流信号的故障特性谐波分量。然后计算故障谐波分量的幅度的信封,并应用D-PMSG的故障诊断。为了验证所提出的方法,在MATLAB / SIMULINK中建立模拟模型,并执行模拟。结果表明,该方法是有效的,其中成功检测到叶片不平衡和绕组不对称断层。