The presence of unbalanced voltage sag in grid actual operation gives rise to the output power fluctuation of PV inverter, the increasing of output current harmonics and unbalanced current. The calculation of the output current reference is a key technology in the control of PV inverter and has important influence on the output of the PV inverter under unbalanced grid voltage. Base on the instantaneous power theory, this paper proposed a calculation method of PV inverter current reference under unbalanced voltage sag. The proposed method will not bring harmonic current problems, with the benefits of selectively elimination of active power fluctuations, reactive power fluctuations or negative sequence component. In addition, the inverter output active and reactive power fluctuation can be flexibly adjusted by changing the value of the variable given in the proposed calculation method. Theoretical analysis and simulation results verify the validity of the proposed calculation method of current reference.
机译:电网实际运行中不平衡电压突降的存在会引起光伏逆变器的输出功率波动,输出电流谐波和不平衡电流的增加。输出电流参考值的计算是光伏逆变器控制中的关键技术,在电网电压不平衡的情况下,对光伏逆变器的输出有重要影响。基于瞬时功率理论,提出了一种不平衡电压骤降下光伏逆变器电流参考的计算方法。所提出的方法不会带来谐波电流问题,具有选择性消除有功功率波动,无功功率波动或负序分量的优点。另外,通过改变所提出的计算方法中给出的变量的值,可以灵活地调节逆变器输出的有功功率和无功功率波动。理论分析和仿真结果验证了所提出的参考电流计算方法的有效性。