首页> 外文会议>IEEE Energy Conversion Congress and Exposition >Analyses of the impact of current load change on a current-mode constant on-time buck converter regulator
【24h】

Analyses of the impact of current load change on a current-mode constant on-time buck converter regulator

机译:电流负载变化对电流模式恒定导通时间降压转换器稳压器的影响分析

获取原文

摘要

For recent energy-saving computer power converter products, it's required to provide a very tightly regulated voltage under very stringent current load change conditions. In this paper, this issue is dealt with for a current-mode constant on-time buck converter. An issue about beat frequency effects analysis is first given using modulation spectrum theory and small-signal frequency-domain model. This analysis provides insight into the complexity of the issue. Then a time-domain approach is used to derive converter output voltage ripple in terms of converter load current excitation. The results are verified in experiments. A mathematical solution is established for estimating the worst-case output ripple voltage due to repetitive large-step AC load current excitation of wide-range frequencies.
机译:对于最新的节能计算机电源转换器产品,要求在非常严格的电流负载变化条件下提供非常严格的稳压电压。本文针对电流模式恒定导通时间降压转换器解决了这个问题。首先利用调制频谱理论和小信号频域模型给出了有关拍频效应分析的问题。该分析可深入了解问题的复杂性。然后使用时域方法根据转换器负载电流激励得出转换器输出电压纹波。实验验证了结果。建立了一种数学解决方案,用于估算由于宽范围频率的重复大步幅交流负载电流激励而导致的最坏情况下的输出纹波电压。