首页> 外文会议>International exhibition conference for power electronics, intelligent motion, renewable energy and energy management >Prediction of Conducted EMI in Power Converter with front-end Three-phase Diode-bridge in Frequency Domain
【24h】

Prediction of Conducted EMI in Power Converter with front-end Three-phase Diode-bridge in Frequency Domain

机译:前端三相二极管桥在频域中的功率变换器中的传导EMI预测

获取原文

摘要

This paper investigates the prediction of conducted EMI in power converters in frequency domain with parameters extraction based on numerical methods. The investigated object of the paper has been limited to power converter with front-end three-phase diode-bridge for rectifying AC grid side voltage to DC voltage. The paper firstly describes the procedure of parameters extraction using numerical methods and then discusses the difficulties of applying frequency domain simulation for this type of converter. Subsequently, methods are explained and proposed for conducted EMI prediction in frequency domain for different detector types. At the end, the frequency domain simulation results are compared to experimental and time domain simulation results, which verify the techniques used.
机译:本文采用基于数值方法的参数提取方法,研究了功率变换器在频域中的传导EMI预测。本文的研究对象仅限于带有前端三相二极管电桥的功率转换器,用于将交流电网侧电压整流为直流电压。本文首先介绍了使用数值方法进行参数提取的过程,然后讨论了将频域仿真应用于此类转换器的困难。随后,解释并提出了针对不同检测器类型在频域中进行EMI预测的方法。最后,将频域仿真结果与实验和时域仿真结果进行比较,从而验证了所使用的技术。