Intensity standardization in breast MR images improves tissue quantification

机译:乳房MR图像中的强度标准化可改善组织量化

获取原文
获取外文期刊封面目录资料

摘要

Computerized algorithms are increasingly being developed for quantifying breast MRI features for facilitating lesion detection and breast tissue segmentation in various clinical applications. One of the current impediments is the intensity non-standardness of the breast tissue in the acquired MR images across different cases, scanners, and/or patients. This degrades the performance of quantitative image processing. In this work, we investigate the usefulness of post-hoc intensity standardization of breast MR images by using a landmark-based nonlinear intensity mapping algorithm. The standardization algorithm is applied after correction of the images for background bias field non-uniformity. We then quantitatively compare the percentage coefficient of variation (%CV) of image intensity in the fibroglandular (e.g., dense) tissue region before and after standardization to evaluate the standardization procedure. In our experiments, we use 9 representative 3D bilateral breast MRI scans/cases constituting 18 breasts (a total of 504 tomographic breast MRI slices), in which we observe a significant decrease of the %CV in the standardized images, indicating that standardization significantly reduces the intensity variation for the fibroglandular tissue across these cases. Furthermore, we demonstrate for two segmentation methods that the standardization process leads to improved segmentation of the fibroglandular tissue. Our work suggests that intensity standardization following bias field correction may serve as an effective preprocessing step to support improved quantitative breast MR image processing and analysis, particularly for breast density quantification.
机译:越来越多地开发用于量化乳房MRI特征的计算机算法,以促进各种临床应用中的病变检测和乳房组织分割。当前的障碍之一是在不同病例,扫描仪和/或患者中所获取的MR图像中乳房组织的强度非标准。这降低了定量图像处理的性能。在这项工作中,我们通过使用基于地标的非线性强度映射算法来研究乳房MR图像的事后强度标准化的有用性。在针对背景偏置场不均匀性对图像进行校正之后,应用标准化算法。然后我们定量比较标准化前后的纤维腺(例如密实)组织区域中图像强度的变化百分比系数(%CV),以评估标准化程序。在我们的实验中,我们使用了9个具有代表性的3D双边乳腺MRI扫描/构成18个乳腺的病例(总共504个乳腺MRI断层扫描切片),其中我们观察到标准化图像中的%CV显着降低,表明标准化显着降低了在这些情况下,纤维腺组织的强度变化。此外,我们证明了两种分割方法,标准化过程可改善纤维腺组织的分割。我们的工作表明,偏置场校正后的强度标准化可以作为有效的预处理步骤,以支持改进的定量乳腺MR图像处理和分析,尤其是对于乳腺密度定量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号