摘要

Congested existing buried piping or pipeline networks "within" or "close to" old plant facilities such as, gathering centers, booster stations, pipeline manifolds, etc. are normally electrically continuous to each other and are protected by common impressed current cathodic protection (CP) systems. However, new Pipeline/piping sections installed at such congested network are sometimes required to be electrically isolated from existing pipelines and are provided with separate impressed current CP systems. This paper discusses, methods implemented in design, installation, testing and commissioning of CP system of electrically isolated new pipeline sections, with special emphasis on DC stray current interference due to existing anode ground beds and existing pipelines crossing/parallelism. Case studies are included, with discussions on results of interference testing, interference mitigation, post interference mitigation surveys and protective potential surveys.
机译:现有的“内部”或“附近”工厂设施(如集水中心,增压站,管道歧管等)内或附近的拥挤埋地管道或管线网络通常彼此电气连续,并受到共同的外加电流阴极保护(CP)的保护。 )系统。但是,有时需要在这种拥挤的网络上安装新的管道/管道部分,使其与现有管道电气隔离,并配备独立的现有CP系统。本文讨论了在电气隔离的新管道部分的CP系统的设计,安装,测试和调试中实施的方法,并特别强调了由于现有阳极接地层和现有管道交叉/平行导致的DC杂散电流干扰。包括案例研究,并讨论了干扰测试,缓解干扰,缓解干扰后调查和保护性潜力调查的结果。