The mathematical models of the surface-mounted permanent magnet synchronous machine (SPMSM) in both healthy and turn fault conditions are utilized to generate the current residual with the same voltage input. The features in the current residual are analyzed with the consideration of model accuracy. The 2 harmonic in the positive rotating dq reference or the dc component in the negative rotating dq reference can be extracted as the fault indicator. To estimate the dc component in the negative rotating reference that is more accurate and robust to transient states, a periodical integral is used in favor of conventional filtering or fast Fourier transform (FFT). It can be shown that the proposed fault detection scheme can distinguish the effect of speed or torque transient from the fault, thus giving a more reliable detecting result. The proposed technique is verified by simulation on a 12-slot, 14-pole SPMSM under various operating conditions.
机译:表面安装的永磁同步机(SPMSM)的数学模型在健康和转动故障条件中用于产生具有相同电压输入的电流剩余。通过考虑模型精度来分析当前残差中的特征。可以提取正旋转DQ参考的2次谐波参考或在负旋转DQ参考中的DC分量作为故障指示器。为了估计在负旋转参考中的DC分量,对瞬态状态更准确且稳健的,期刊积分用于传统的过滤或快速傅里叶变换(FFT)。可以表明,所提出的故障检测方案可以将速度或扭矩瞬态的效果与故障区分开,从而提供更可靠的检测结果。在各种操作条件下通过在12插槽14极SPMSM上进行仿真来验证所提出的技术。