摘要

Rural and suburban areas in Finland mainly implement overhead lines for distribution at the 20 kV level. Large scale outages resulting from severe storms have added pressure to develop weather-proof distribution networks. Replacement of existing overhead line systems with traditional cables and traditional installation techniques is far too expensive an operation to undertake. As such, the development of novel cable installation methods are required along with new types of cables. A new cable design with reduced insulation intended for both underground and overhead installation was investigated as part of a sustainable community research program. Although the thickness of the new cable insulation differs from IEC standard nominal values, the new cable design successfully passed large scale electrical testing according to international and national standards. Cable accessories including terminations for indoor and outdoor installations and cable joints also passed the testing routines. From the tests it was concluded that the quality of the installation work is crucial - the observed issues are not related to the insulation system' but to the quality of installation and assembly. Thus, this crucial point requires particular attention in real installations.
机译:芬兰的农村和郊区主要实施架空线,以20 kV的水平进行配电。暴风雨造成的大规模停电增加了开发耐候性配电网络的压力。用传统的电缆和传统的安装技术来替换现有的架空线系统实在太昂贵了。因此,需要与新型电缆一起开发新颖的电缆安装方法。作为可持续社区研究计划的一部分,对用于地下和高架安装的绝缘降低的新电缆设计进行了研究。尽管新电缆绝缘层的厚度与IEC标准标称值不同,但新电缆设计已成功通过了根据国际和国家标准的大规模电气测试。电缆附件(包括用于室内和室外安装的终端以及电缆接头)也通过了测试程序。从测试得出的结论是,安装工作的质量至关重要-所观察到的问题与绝缘系统无关,而与安装和组装的质量有关。因此,这一关键点在实际安装中需要特别注意。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号