首页> 外文会议>IEEE International Instrumentation and Measurement Technology Conference >A Novel Sensor for Wrist Based Optical Heart Rate Monitor
【24h】

A Novel Sensor for Wrist Based Optical Heart Rate Monitor

机译:一种用于腕部光学心率监测器的新型传感器

获取原文

摘要

The growing demands of continuous healthcare and hence physiological monitoring necessitates a system with high reliability and accuracy. Wearable used for continuous cardiological parameter estimation from wrist use reflective photoplethysmography technique that has certain limitations which are imperative. One such constraint is skin pigmentation of the subject. In the present work a sensor module design is proposed addressing to the anomalies due to optical properties of skin. A novel 590 nm (yellow-orange) wavelength based optical system is tailored suitably to maximize the signal quality acquired. The proposed setup is validated on a conglomeration of subjects in terms of age, gender and skin tone. A generous agreement between coherent measures for signal quality shows that the proposed wavelength holds an advantage over its shorter counterpart when subjected to varied skin pigmentation levels. A maximum improvement factor of 71 is observed in case of perfusion index, 31 for pulsatile strength and 3 for SNR. The details of sensor design, experimental setup, validation protocol, observations and inferences drawn from the study are presented.
机译:不断增长的连续医疗保健,因此生理监测需要具有高可靠性和准确性的系统。可穿戴用于腕带的连续心脏病学参数估计,使用具有一定限制的反射光电精测方法,其势在必行。一种这种约束是受试者的皮肤色素沉着。在本工作中,由于皮肤的光学性质,提出了传感器模块设计。一种新颖的590nm(黄橙色)波长的基于光学系统,适当地定制,以最大化所获取的信号质量。在年龄,性别和肤色方面,拟议的设置验证了受试者的集合。信号质量相干措施之间的慷慨协议表明,当受到变化的皮肤色素沉着水平时,所提出的波长在其较短的对应上具有优势。在灌注指数的情况下观察到71的最大改善因子,31用于脉动强度和3用于SNR。提出了从研究中汲取的传感器设计,实验设置,验证协议,观察和推断的细节。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号