Three Litz wires have been used in parallel in order to decrease the layer to layer voltage down to 4 kV and the coil voltage down to 8 kV. A two millimeter thick epoxy plate has been glued between each layer, in order to prevent any electrical breakdown between the layers. A special epoxy has been used to minimize the inner temperature of the coil, which reached 180 °C with a dissipated power of 5.2 kW. The use of parallel Litz wire leads to currents having different phase angle in every wire which has to be corrected.
机译:为了降低层间电压至4 kV和线圈电压至8 kV,已并联使用三根Litz导线。为了防止各层之间发生任何电击穿,在各层之间粘贴了两毫米厚的环氧树脂板。为了降低线圈的内部温度,使用了一种特殊的环氧树脂,线圈的内部温度达到了180°C,耗散功率为5.2 kW。使用平行的利兹线会导致电流在每根线中具有不同的相位角,必须对其进行校正。