A system of VLD's (Voltage Limiting Devices) is installed in the Copenhagen Metro traction system. The purpose of having these VLD's is electrical safety. At every Metro station a "57-VLD" is installed. The VLD's will be switched on automatically if the potential at the running rail exceeds the potential at the earthing system by more than 90 volt. Such incidents are not very common according to Metroselskabet, and the duration of such short-circuiting incidents is short. In addition to the automatic activation of VLDs every night for five days a week, maintenance work is also carried out at specific parts of the Metro track system. This maintenance is scheduled where specific parts of the track system are taken out of service for about 5 hours. During these periods the VLD's in each end of the mentioned sections are switched on for the safety of the workers. Even when one VLD is switched on (possible scenario for the automatic activation), the track system is changed from being electrically "floating" to a system where stray currents may enter or leave the track system through the VLD. The paper presents 1) A risk evaluation of stray current corrosion risk for the Metro 2) a mathematical simulation of the electrical currents where a number of the "57- VLD's" are activated. 3) Monitoring results of the track system during periods where a number of the "57-VLD's" are activated. The monitoring results are in line with the mathematical simulation of the electrical currents and it is found that VLDs comprise a considerable corrosion risk that should be considered.
机译:哥本哈根地铁牵引系统中安装了VLD(限压设备)系统。具有这些VLD的目的是电气安全。在每个地铁站都安装了“ 57-VLD”。如果运行导轨上的电势超过接地系统上的电势超过90伏,则VLD将自动打开。根据Metroselskabet,此类事件不是很常见,并且此类短路事件的持续时间很短。除了每周五天每天晚上自动激活VLD之外,还在地铁轨道系统的特定部分进行维护工作。计划进行此项维护,其中轨道系统的特定部分停运了约5个小时。在此期间,为了确保工人的安全,将打开上述各部分中的VLD。即使打开一个VLD(可能是自动激活的情况),轨道系统也已从“浮动”状态变为杂散电流可能通过VLD进入或离开轨道系统的系统。本文介绍了1)地铁对杂散电流腐蚀风险的风险评估; 2)激活了许多“ 57-VLD”的电流的数学模拟。 3)在激活多个“ 57-VLD”期间,跟踪系统的监视结果。监测结果与电流的数学模拟相符,并且发现VLD具有相当大的腐蚀风险,应予以考虑。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号