首页> 外文会议>ASME international mechanical engineering congress and exposition;IMECE2011 >Gas Mass Flow Rate Measurement in T-Shaped Microchannels in Slip Flow Regime
【24h】

Gas Mass Flow Rate Measurement in T-Shaped Microchannels in Slip Flow Regime

机译:滑流条件下T型微通道的气体质量流量测量

获取原文

摘要

A new setup was developed for gas mixing analysis in T-shaped microchannels. The principle of the flow rate measurement was based on the Constant Volume (CV) method [1]. The mass flow rate measurements of two gases N_2/ CO_2 mixing in a T mixer were carried out in the slip flow regime and followed by a simulation work for comparison. The mass flow rate has a magnitude of 10~(-8) or 10~(-7) kg/s and has good agreement with simulation for the lowest inlet over outlet pressures ratios and moderate agreement for the highest inlet over outlet pressures ratios.
机译:开发了一种用于在T形微通道中进行气体混合分析的新装置。流量测量的原理基于恒定体积(CV)方法[1]。在滑流状态下对在T混合器中混合的两种气体N_2 / CO_2的质量流率进行了测量,然后进行了仿真工作以进行比较。质量流量的大小为10〜(-8)或10〜(-7)kg / s,并且与最低进风口压力比的模拟仿真具有良好的一致性,对于最高进风口压力比的仿真具有良好的一致性。