首页> 外文会议>PVP2011;ASME Pressure Vessels and Piping conference >HIGH TEMPERATURE DESIGN AND DAMAGE EVALUATION OF MOD.9CR-1MO STEEL HEAT EXCHANGER
【24h】

HIGH TEMPERATURE DESIGN AND DAMAGE EVALUATION OF MOD.9CR-1MO STEEL HEAT EXCHANGER

机译:MOD.9CR-1MO钢制换热器的高温设计和损伤评估

获取原文

摘要

High temperature design and evaluation of creep-fatigue damage for sodium-sodium heat exchanger, DHX (Decay heat exchanger) in a sodium test loop have been conducted. The DHX is a shell- and tube-type heat exchanger with outer diameter of 21.7mm, thickness of 1.65mm and effective length of 1.73m. The DHX shell and tube materials were Mod.9Cr-1Mo steel. The temperatures of shell inlet and shell outlet in the DHX are 510°C and 308°C, respectively, while the temperatures of tube inlet and outlet are 254°C and 475°C, respectively. Three dimensional finite element analysis was conducted for the DHX and evaluation of creep-fatigue damage at several critical locations of the heat exchanger was carried out according to the elevated temperature design codes of the ASME Section III Subsection NH and RCC-MR. Evaluations on the integrity of the DHX and code comparisons were carried out for the critical locations of the DHX.
机译:钠钠钠 - 钠钠蒸发器的高温设计和评价钠 - 钠 - 钠 - 乳酸钠损伤,DHX(腐烂热交换器)已经进行了钠试验回路。 DHX是外径21.7mm,厚度为1.65mm,长度为1.73m的壳体和管式热交换器。 DHX壳和管材料是MOD.9CR-1MO钢。 DHX中壳体入口和壳体出口的温度分别为510℃和308°C,而管入口和出口的温度分别为254°C和475°C。对于DHX进行三维有限元分析,并根据ASME第III款NH和RCC-MR的升高的温度设计代码进行热交换器的近几个关键位置处的蠕变疲劳损伤的评价。对DHX和代码比较的完整性的评估是针对DHX的关键位置进行的。