In an unbalanced nulling interferometer (UNI) of our coronagraph system, the incidence light is divided into two, and they interfere by a reverse phase with different amplitude. Thereby, phase errors are magnified and we can correct a wavefront with higher precision. But phase errors of the incident wave will be magnified together with the wavefront errors inside UNI. Now, I am developing a control algorithm of the adaptive optics which removes the wavefront errors inside the interferometer by operating the phase of the light to a suitable value before dividing. In a simulation, wavefront accuracy improved by about 3 times with this technique, and also a comparable effect was acquired experimentally.© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
机译:在我们的日冕仪系统的不平衡调零干涉仪(UNI)中,入射光被分为两部分,并且它们受到具有不同幅度的反相的干扰。由此,相位误差被放大,并且我们可以以更高的精度校正波前。但是,入射波的相位误差将与UNI内部的波前误差一起放大。现在,我正在开发一种自适应光学系统的控制算法,该算法通过在分频之前将光的相位操作为合适的值来消除干涉仪内部的波前误差。在仿真中,使用此技术可将波前精度提高约3倍,并且通过实验获得了可比的效果。©(2012)COPYRIGHT光电仪器工程师协会(SPIE)。摘要的下载仅允许个人使用。