The formation of calcium carbonate scale and the occurrence of CO_2 corrosion in sweet environments are both widespread phenomena and have been studied extensively in oil and gas industry. Scale and corrosion are part of the main problem encountered in distillation plants or in flow assurance for oil and gas industry. Investigations centred on inhibition tend to focus on reducing scale and corrosion through individual chemical treatments as opposed to inhibiting both processes with one chemical inhibitor. Scope exists for a combined product which is capable of retarding both the effects of scale formation and CO_2 corrosion. This paper presents results from an initial trial that has been conducted to develop a methodology based on a bulk jar scaling test and a bubble cell corrosion measurement. The efficiency of four combined corrosion and scale inhibitors were assessed while both scaling and corrosion processes were occurring on X-65 carbon steel samples. The formation and growth of scale in the bulk was monitored using a turbidity meter and the corrosion rate was assessed through linear polarisation resistance measurement. The four combined products were studied at different concentrations (2, 4 and 5ppm) at 60°C in CO_2- saturated brine. Scanning Electron Microscopy (SEM) was used to examine the surface morphology of the samples after the experiments. According to the results, the combined products act by increasing the induction time of the formation of the calcium carbonate in the bulk, changing the morphology of the crystals and forming a partial protective layer onto the sample. Each chemical reveals a different efficiency in inhibiting the scale and/or the corrosion process.
机译:碳酸钙结垢的形成和甜环境中CO_2腐蚀的发生都是普遍现象,已在石油和天然气工业中进行了广泛的研究。结垢和腐蚀是蒸馏厂或油气行业流量保证中遇到的主要问题的一部分。与抑制作用有关的研究倾向于集中于通过单独的化学处理来减少水垢和腐蚀,这与用一种化学抑制剂来抑制这两个过程相反。存在能够同时抑制水垢形成和CO 2腐蚀的作用的组合产品的范围。本文介绍了一项初步试验的结果,该试验已经进行,目的是开发基于散装罐垢试验和气泡池腐蚀测量的方法。在X-65碳钢样品上进行结垢和腐蚀过程的同时,评估了四种组合的缓蚀剂和阻垢剂的效率。使用浊度计监测大块中水垢的形成和生长,并通过线性极化电阻测量来评估腐蚀速率。在60°C的CO_2饱和盐水中以四种不同浓度(2、4和5ppm)研究了这四种组合产物。实验后,使用扫描电子显微镜(SEM)检查样品的表面形态。根据结果​​,组合产物的作用是通过增加本体中碳酸钙形成的诱导时间,改变晶体的形态并在样品上形成部分保护层来实现的。每种化学品在抑制水垢和/或腐蚀过程方面显示出不同的效率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号