This paper presents a locating method for multiple partial discharge (PD) sources based on the maximum a posteriori estimation. The feature of this method lies in monitoring an entire substation. The sensors installed in the monitoring area such as the substation receive PD signals and estimate the direction of arrival angles. Then integrating all the estimated angles provides source positions. The capability of the proposed system was confirmed by numerical simulations. The results include the comparison of performance for the number of sensors.
机译:本文提出了一种基于最大后验估计的局部放电(PD)源的定位方法。该方法的特点在于监视整个变电站。安装在监视区域(例如变电站)中的传感器接收PD信号并估计到达角度的方向。然后,对所有估计的角度进行积分即可提供源位置。数值仿真证实了所提出系统的功能。结果包括传感器数量的性能比较。