首页> 外文会议>2011 International Conference on Electrical and Control Engineering >Study of performance of sequencing batch membrane aerated biofilm reactor for simultaneous nitrogen and phosphorus removal
【24h】

Study of performance of sequencing batch membrane aerated biofilm reactor for simultaneous nitrogen and phosphorus removal

机译:序批式膜曝气生物膜反应器同时脱氮除磷性能的研究

获取原文

摘要

A sequencing batch membrane aerated biofilm reactor (SBMABR) was developed to treat nitrogenous and phosphorous municipal wastewater. Tests were conducted to investigate the feasibility of simultaneous nitrogen and phosphorus removal. The results showed that simultaneous anoxic phosphate uptake and biological denitrification with good performance could be obtained in SBMABR operated in steady state. NH4+-N, total phosphorus (TP) and chemical oxygen demanding (COD)removal efficiency could be maintained at 90 %, 84.5 % and 87 %, respectively, under the conditions of intra-membrane pressure of 0.025 MPa, hydraulic retention time (HRT) of 8 h and one cycle of 2.5 h (anaerobic phase of 1 h and membrane aeration phase of 1.5 h), and the accumulation of nitrite and nitrate was not observed clearly.
机译:开发了一种顺序批式膜曝气生物膜反应器(SBMABR),用于处理含氮和含磷的城市废水。进行测试以调查同时去除氮和磷的可行性。结果表明,在稳定状态下运行的SBMABR能够同时获得良好的缺氧磷酸盐和生物反硝化性能。在0.025 MPa的膜内压力,水力停留时间(HRT)的条件下,NH4 + -N,总磷(TP)和化学需氧量(COD)的去除效率分别可保持在90%,84.5%和87%。 8小时)和2.5小时的一个循环(厌氧阶段为1小时,膜通气阶段为1.5小时),并且没有清楚地观察到亚硝酸盐和硝酸盐的积累。