For the design of industry building, it is necessary to combine the equipment system with structure system into structure-equipment coupled system in some cases. It can accurately show the interaction between structure and equipment. According to the earthquake disaster phenomena of equipments, the failure modes and failure criteria are researched. The seismic performance levels and fortification objects of structure-equipment coupled system are presented. The failure criteria of structure-equipment coupled system are also analyzed. Finite element analysis on the direct air cooled condenser platform is done. According to the numerical calculation and the test data, the seismic performance objectives for the direct air cooled condenser platform structure-equipment coupled system are presented, which can be employed by the structural design.
机译:对于行业建筑的设计,在某些情况下,有必要将设备系统与结构系统结合到结构 - 设备耦合系统中。它可以准确地显示结构和设备之间的相互作用。根据设备的地震灾害现象,研究了失败模式和故障标准。提出了结构 - 设备耦合系统的地震性能水平和设防物体。还分析了结构 - 设备耦合系统的故障标准。直接风冷冷凝器平台的有限元分析完成。根据数值计算和测试数据,提出了用于直接风冷冷凝器平台结构 - 设备耦合系统的地震性能目标,其可以通过结构设计来采用。