The SMART (System-integrated Modular Advanced ReacTor) is small sized integral type pressurized water reactor designed by KAERI (Korea Atomic Energy Research Institute), Korea. But, shape of steam generator (SG) in SMART plant differs from those in operated nuclear power plants (NPPs). Especially, SG tubes in SAMRT plant is helical type with around 600 mm of innermost diameter and thickness of 2.5 mm which is thicker than general NPPs one. For providing integrity of SG tube in SMART plant, new types of ECT method are needed because eddy current testing (ECT) is one of widely adopted method for inspection of SG tubes in NPPs.Therefore, in this study, we investigate optimal conditions or parameters for detecting and evaluating of flaws in the SG tubes in SMART plant by simulation of ECT signals with various testing condition or parameter such as frequency, coil gap and etc. From the simulated ECT signals optimal eddy current test condition or parameters are proposed.
机译:SMART(系统集成模块化先进反应堆)是韩国KAERI(韩国原子能研究所)设计的小型整体式压水反应堆。但是,SMART工厂中的蒸汽发生器(SG)的形状与运行中的核电站(NPP)中的蒸汽发生器(SG)的形状有所不同。特别是,SAMRT工厂中的SG管是螺旋形的,最内径约为600毫米,厚度为2.5毫米,比一般的NPP还要厚。为了在SMART工厂中提供SG管的完整性,由于涡流测试(ECT)是NPP中检查SG管的一种广泛采用的方法之一,因此需要新型的ECT方法。 因此,在这项研究中,我们通过模拟具有各种测试条件或参数(例如频率,线圈间隙等)的ECT信号,来研究用于检测和评估SMART工厂的SG管中缺陷的最佳条件或参数。提出了最佳涡流测试条件或参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号