This paper investigates the long term corrosion behaviour of pretreated carbon steel under alternating anaerobic to aerobic cycles over 238 days. Changes in steel behaviour were observed electrochemically by monitoring the corrosion potential, and calculating changes to corrosion rate from linear polarization resistance. With increasing cycle number the corrosion process becomes localized at a small number of locations, consistent with the formation of tubercles. Periods of aerobic corrosion were associated with more positive potentials (between -500 mV to -350 mV) and high corrosion rates (70 to 120 urn yr~(-1); whereas anaerobic corrosion yielded more negative potentials (< -650 mV) and lower corrosion rates (40 to 50 um yr~(-1)). Upon termination of the experiment, corrosion product deposits were characterized by several techniques: scanningelectrochemical microscopy to detect morphology; focused ion beam and cross sectioning to judge film thickness and film porosity; and Raman Spectroscopy to identify iron phases.
机译:本文研究了在238天内交替厌氧厌氧下预处理碳钢的长期腐蚀行为。通过监测腐蚀电位,通过监测腐蚀电位来观察钢行为的变化,并计算与线性偏振电阻的腐蚀速率的变化。随着循环编号的增加,腐蚀过程在少数位置处变得局限,与结节的形成一致。有氧腐蚀的时期与更高的阳性电位(在-500mV至-350 mV之间)和高腐蚀速率(70〜120 urn Yr〜(-1);而厌氧腐蚀产生更多的负电位(<-650 mV)和降低腐蚀速率(40至50μmYR〜(-1))。在实验终止时,通过几种技术表征腐蚀产品沉积物:扫描 电化学显微镜检测形态;聚焦离子束和横截面判断膜厚度和薄膜孔隙率;和拉曼光谱法识别铁阶段。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号