A balanced, filterless, K-edge energy window multilayer detector for dual energy computed tomography

机译:平衡,无滤波器,K边缘能量窗口多层探测器,用于双能计算机断层扫描

获取原文

摘要

Ross (or balanced) filter-based systems have been studied extensively in the past, however they have only recently been studied for medical applications such as computed tomography and contrast-enhanced mammography. Balanced filters are filters composed of different materials which have thicknesses designed to match the attenuation for all radiation energies except those within a certain energy window (between the K-edges of the filter materials). Images obtained using different filters to attenuate the incident x-rays can be subtracted to obtain an image which contains information solely within the energy window. The disadvantage of this image acquisition method is the requirement of a separate exposure for each filter. This can lead to motion artifacts in the resulting image for example due to cardiac, respiratory, or patient movement.In this paper we investigate a filterless, multilayer detector design using the general concept of balanced filters. In the proposed detector, energy discrimination is achieved using stacked layers of different conversion materials. Similar to how the thicknesses of balanced filters are chosen, the thicknesses of the conversion layers are designed to match the attenuation of x-rays except between the K-edges of the conversion materials. Motion artifacts are suppressed in the final image due to the simultaneous acquisition of images on all layers during a single exposure. The proposed multilayer design can be used for a number of applications depending on the energy range of interest. To study the proposed design, we consider dual energy computed tomography (CT) using a gadolinium-based contrast agent.
机译:过去已经对基于Ross(或平衡)滤波器的系统进行了广泛的研究,但是,直到最近才针对医疗应用(例如计算机断层扫描和造影剂X线摄影)对其进行研究。平衡滤光片是由不同材料组成的滤光片,其厚度设计成与所有辐射能量的衰减相匹配,除了某个能量窗口内(滤光材料的K边之间)的能量。可以减去使用不同滤镜衰减入射X射线获得的图像,以获得仅包含能量窗口内信息的图像。这种图像采集方法的缺点是每个滤光片都需要单独曝光。例如由于心脏,呼吸或患者的运动,这可能导致结果图像中出现运动伪像。 在本文中,我们使用平衡滤波器的一般概念来研究无滤波器的多层检测器设计。在所提出的检测器中,使用不同转换材料的堆叠层来实现能量辨别。类似于如何选择平衡滤光片的厚度,转换层的厚度设计为匹配X射线的衰减,除了转换材料的K边之间。由于在单次曝光期间同时在所有图层上同时获取图像,因此最终图像中的运动伪影得到了抑制。根据感兴趣的能量范围,建议的多层设计可用于多种应用。为了研究拟议的设计,我们考虑使用基于ado的造影剂进行双能计算机断层扫描(CT)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号