首页> 外文会议>IMECE2009;ASME international mechanical engineering congress and exposition >A CASE STUDY ON WINDAGE NOISE DIAGNOSIS REDUCTION IN 10,000 HP HIGH SPEED INDUCTION MOTOR
【24h】

A CASE STUDY ON WINDAGE NOISE DIAGNOSIS REDUCTION IN 10,000 HP HIGH SPEED INDUCTION MOTOR

机译:10,000 HP高速感应电机的风噪诊断与降低的案例研究

获取原文

摘要

Noise in large high voltage induction motors (500Hp and above) may be windage or magnetic in nature. Usually large high voltage induction motors induction motors are custom built and tailored to meet customers demand. In large high speed induction motors sometimes it is difficult to isolate windage noise from magnetic noise as the generated frequencies are similar in magnitude; hence reducing noise after motor is manufactured becomes extremely challenging. This paper will present the noise troubleshooting case study of 10,000Hp induction motor that shows overall noise of 100 dB during the factory testing. A variety of tests (e.g unloaded, variable speed, coupled loaded test and also test motor driven as load) were performed to isolate magnetic noise from air borne noise. Noise FFT data was collected to identify peak noise generating frequencies. Sound intensity and sound pressure data were also collected to calculate overall sound power level. After identifying the cause of noise, motor frame design was modified which results in overall noise level of 85 dB.
机译:大型高压感应电动机(500Hp及以上)中的噪声本质上可能是风阻或磁性。通常,大型高压感应电动机是根据客户要求定制和量身定制的。在大型高速感应电动机中,有时很难将风阻噪声与磁噪声隔离开来,因为所产生的频率大小相似。因此,降低电机制造后的噪音变得非常具有挑战性。本文将介绍10,000Hp感应电动机的噪声故障排除案例研究,该案例研究表明在工厂测试期间总噪声为100 dB。进行了各种测试(例如空载,变速,耦合负载测试以及以负载驱动的测试电动机),以将电磁噪声与空气传播的噪声隔离开。收集噪声FFT数据以识别峰值噪声产生频率。还收集了声音强度和声压数据,以计算总体声功率级。在确定噪声原因后,对电机框架设计进行了修改,从而使总噪声水平达到了85 dB。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号