With the 500kV substations put into operation one after the other, the capacity and scale of 500kV autotransformer are more and more large. The single-phase short-circuit current at 220 kV buses of 500kV substations is higher than three-phase, the safe operation can't be satisfied. It can be controlled by adding small reactance at 500kV autotransformers from the operation experience of all over the world. This paper analyzes the reason and necessity for adding small reactance at 500kV autotransformers from the level of short current on Guangdong, and studies the types of substations which are fit to installing them. It also studies the effect of the small reactance capacity on limiting short-circuit current of single phase, and proposes the installation program for Guangdong power grid.
机译:使用500kV变电站之后的500kV变电站另一个,500kV自耦变压器的容量和等级越来越大。 220 kV母线的单相短路电流为500kV变电站高于三相,无法满足安全操作。可以通过在全球各地的运营体验中增加500kV自耦变压器的小电抗来控制。本文分析了从广东短电流的500kV自耦变压器增加了少量电抗的原因和必要性,研究了适合安装它们的变电站类型。它还研究了小电抗容量对单相短路电流的影响,并提出了广东电网的安装方案。