The method to identify the sources of the neutral-to-earth voltage (NEV) rise as presented in a companion paper is verified in this paper through extensive simulation studies and field measurements. Sensitivity studies are conducted to determine factors that affect the performance of the proposed method. The results show that the NEV contribution factor index is effective in identifying load unbalance caused NEV and its contributors. The current return ratio index is effective in diagnosing poor grounding caused NEV and its contributors. An NEV troubleshooting strategy and a system-wide NEV condition monitoring strategy are proposed based on the findings.