首页> 外文会议>Proceedings of the 2010 5th IEEE International Conference on Nano/Micro Engineered and Molecular Systems >Single-wall carbon nanotube modified glassy carbon electrode for electroanalytical determination of dopamine
【24h】

Single-wall carbon nanotube modified glassy carbon electrode for electroanalytical determination of dopamine

机译:单壁碳纳米管修饰玻碳电极用于多巴胺的电分析测定

获取原文

摘要

In this research, a glassy carbon electrode modified with single-wall carbon nanotubes for electrochemical determination of dopamine was studied by cyclicvoltammetry (CV) and differential pulse voltammetry (DPV). The oxidation and reduction potentials of dopamine using voltammetric technique were measured. The SWCNTs/GC 10 µL was used to test the linearity of anodic oxidation of dopamine by DPV. The peak current increased linearly with concentration of dopamine in the range of 2.5–25 ppm (R2 =0.9766). For the life time of the SWCNTs/GC, the cut-off criterion of the DPV was detected in the reduction of current by 50 %. The lifetime of the SWCNTs-modified depended on the oxidation of dopamine because of fouling of the electrode surface due to the adsorption of oxidation products. 34 repetition cycles was obtained. The detection limit of the dopamine as obtained from the oxidation current in DPV was 0.021 ppm (S/N=3) with minimum current for the detection of dopamine of 0.033 µA. The reproducibility of electrocatalytical studies was better within 90% (10% RSD). The relative standard deviation (RSD) of 8.42% for 100 ppm dopamine (n=20) showed excellent reproducibility. Drug samples obtained from Radvitee hospital were tested as the mentioned procedure. The percentage recovery of dopamine in drug samples was 120.
机译:在这项研究中,通过循环伏安法(CV)和微分脉冲伏安法(DPV)研究了用单壁碳纳米管修饰的玻璃状碳电极,用于电化学测定多巴胺。使用伏安法测量了多巴胺的氧化和还原电位。 SWCNTs / GC 10 µL用于测试DPV对多巴胺进行阳极氧化的线性。峰值电流随着多巴胺浓度在2.5–25 ppm范围内线性增加(R 2 = 0.9766)。在SWCNTs / GC的使用寿命中,检测到DPV的截止标准是电流降低了50%。改性的SWCNT的寿命取决于多巴胺的氧化,这是由于由于氧化产物的吸附而导致电极表面的结垢。获得了34个重复周期。由DPV中的氧化电流获得的多巴胺的检出限为0.021ppm(S / N = 3),用于检测多巴胺的最小电流为0.033μA。电催化研究的可重复性在90%(RSD为10%)内更好。 100 ppm多巴胺(n = 20)的相对标准偏差(RSD)为8.42%,显示出优异的重现性。按照上述步骤测试从Radvitee医院获得的药物样本。药物样品中多巴胺的回收率为120。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号